9.4 Customer Factoryparametersets
The reader LFM 4x can be delivered with a few Factoryparametersets. The settings of the
Factoryparameterset is part of the factory settings and can only be changed by Hermos. If
customer needs another Factoryparameterset setting, please ask Hermos for the
necessary steps. The installed Factoryparameterset can be read by parameter 64 (use
command “G164”).
Factoryparameterset 0: (standard ASC-I1 mode)
The antenna will be addressed by the ReaderID or TargetID „1“ to „4“.
At the rs232 connector a HFS ESN reader is connected and can be adressed by ReaderID
“5”. For SECS protocol there is no MID area defined.
Factoryparameterset 1: (standard ASC-I1 mode)
The antenna will be addressed by the ReaderID or TargetID „1“ to „4“. For SECS protocol
there is no MID area defined.
The rs232 connector can be used for serial host communication.
Factoryparameterset 2: (standard ASC-I1 mode)
The antenna will be addressed by the ReaderID or TargetID „1“ to „4“.
For SECS protocol the default MID area of 2 pages / 16 characters is defined. The rs232
connector can be used for serial host communication.
Factoryparameterset 3: (ASC-W1 mode)
The antenna is addressed by the ReaderID „0“ to „3“, or TargetID „1“ to „4“. For SECS
protocol there is no MID area defined.
The rs232 connector can be used for serial host communication.
For the TCP/IP communication the complete end packet of the ASCI-I1 protocol will be
transmitted (end character and 4 bytes checksum).
P-command: The parameter value will be interpreted as hexadecimal value.
The additional F-command can be used to deliver the parameter value with hexadecimal
interpretation. X/R/W-command: The page value will be interpreted as hexadecimal value.
Errors will be send with the command “E”. With default settings a confirmation has to be
send. The additional B-command can be used for signal the detection of an object.
Factoryparameterset 4: (standard ASC-I1 mode)
The antenna will be addressed by the ReaderID „0“ to „3“ or TargetID „1“ to „4“.
For the SECS protocol, the standard MID range of 2 pages / 16 characters is defined. The
RS232 port can be used for serial host communication.
Factoryparameterset 5: (standard ASC-I1 mode)
The antenna will be addressed by the ReaderID „0“ to „3“ or TargetID „1“ to „4“.
For the SECS protocol, the standard MID range of 2 pages / 16 characters is defined. The
RS232 port can be used for serial host communication.
This mode supports the 24 volt I / O module with 6 sensors and 8 outputs. The two
additional sensors are represented by an extended range for ReaderID or Portnumber
PTN.