User Manual
HERMOS AG
Gartenstraße 19 • 95490 Mistelgau
Phone: +49 9279 991 - 0
E-mail: rfid@hermos.com
LFM 4x Reader Rev1.4
back to the table of contents
68
www.hermos.com
Customer manual
LFM 4x Reader
RFID
WE GENERATE SOLUTIONS
The following examples are based on the standard ASC-I1 protocol. The range of the Reader
ID is set from 1 to 4 in this case:
V – Query software version
>> V1
<< v14C464D3449312E35
Command V
Reader-ID 1
Software version ‚4C464D3449312E35 ‘
ASCII „ LFM4I1.5“
I – automatically tune RF module (antenna port 2)
>> I208
<< i2
Commandl I
Reader-ID 2 (Tuning Antenna port 2)
J – RF module Read out tuning value (Antenna port 2)
>> J2
<< j201
Command
J
Reader-ID
2
(Antenna port 2)
Data
01
(voting value)
X – Read data (Reading from page 1 of the multipage transponder)
>> X101
<< x1014142434445464748
Command X
Reader-ID 1 (reading on antenna port 1)
Page 01
Data
‚4142434445464748‘
ASCII „ABCDEFGH“
R - Automatic reading on antenna port 1
<< R1013132333435363738
>> r1
Command R
Reader-ID 1 (automatic reading on antenna port 1)
Page 01
Data
‚4142434445464748‘
ASCII „ ABCDEFGH „
W – Write data (Write antenna port 2, page 16 Multipage)
>> W2103132333435363738
<< w2
Command W
Reader-ID 2 (Write to antenna port 2) Page 10 (10hex = page 16dec.)
Data
‚3132333435363738‘
ASCII „12345678“