User Manual

HERMOS AG
Gartenstraße 19 • 95490 Mistelgau
Phone: +49 9279 991 - 0
E-mail: rfid@hermos.com
LFM 4x Reader Rev1.4
back to the table of contents
70
www.hermos.com
Customer manual
LFM 4x Reader
RFID
B
Unconfig
Maximum number of
send messages has
been confirmed
(RS232 maxrepeat),
The terminal did not
confirm within the
specified timeframe
Host system does not
acknowledge the
message
Check availability oft he host
system, Check RS232 cable and
connector Ethernet cable and
connector, Check IPAddress
settings
C
Bad type
Wrong transponder
type
A wrong transponder type
is used (Read only or
Read / Write instead of
multipage)
Check and replace transponder
type
:
Msg len
Message too long or
too short
or not received
completely
Message too long or too
short or
not received completely
Message length is longer than
indicated on the length byte,
Check message length and length
byte
Message is longer than
specified in the length
byte
Check message length, check
length byte
Not all characters are
transfered (Intercharacter
Timeout)
Check message syntax, Check
RS232 or Ethernet connection
;
Invalid
Invalid command
Unknown command was
received
Check message syntax