SELF_TEST_RESULT“ Returns the result of the last self-test. A self-test can
be triggered by message S18F13 using SSCMD.
MANUFACTURER“ String from the manufacturerHERMOS
ECID_00 bis ECID_99 see data element ECV parameters 0 - 99
Head attribute definitions:
HeadStatus Current state
IDLE Reader in REST mode
BUSY reader is busy
NOOP Not in operation
HeadID“ corresponds to the 2-digit target ID of the first antenna port
„01“ or „00“
Where used S18F2, S18F3
State request value
OpStatus Operating status, maintenance or rest mode
„OP“ ... operating status
„MT“ ... maintenance status
LEDStatus LED-status
Off“ ... switch off the LED
On“ ... switch on the LED
„Flash“ ... switch the LED to flashing mode with 1Hz
LedNo LED-number, 1 Byte
„1“ first LED of the Reader Heads (if available)
„2“ second LED of the Reader Heads (if available)
„3“ red status LED of the reader
„4“ green status LED of the reader
Timeout Timeout duration, Units seconds
„00“: permanently
„01“ bis „FF“: Timeout from 1 to 255 s. After the timeout, the LED goes off.
Where used S18F13
The number of LEDs per antenna input depends on the design of the
hardware.
CPVAL Format: A[]