User Manual

Customer manual
LFM 4x Reader
RFID
HERMOS AG
Gartenstraße 19 • 95490 Mistelgau
Phone: +49 9279 991 - 0
E-mail: rfid@hermos.com
LFM 4x Reader Rev1.3
back to the table of contents
82
www.hermos.com
Value of the reader parameter.
The values are displayed as decimal values, see parameters.
Where used S2F14, S2F15
Plant model number (Hardware version)
Where used S1F2
Material Format Code
20: The material port number corresponds to the sensor number and the sensor status.
Where used S3F5, S3F7
The data element MHED consists of the head of the SECS message block associated with the defective
message block.
Where used S9F1, S9F3, S9F5, S9F9
Material ID, predefined area on the transponder in which the unique identifier of the cassette / box is
stored. Depending on the type of transponder, the length of the MID can be changed.
Multipage-Transponder: The MID length can be set from „0 (no MID) to 10 (MID occupies
the first 10 pages).
Read-Write-Transponder: The MID corresponds to the DATA (writable) Read-Only-
Transponder: The MID corresponds to the DATA (fixed)
Where used S18F10, S18F11
Please note the parameters 42-45
ECV Format: U1
MDLN Format: A[6]
MF Format: B[1]
MHEAD Format: B[10]
MID Format: A