User's Manual

Table Of Contents
12
Tail
Tail: 24 bytes
Field
Bytes
Description
Reserved
6
-
High Temperature
Shutdown Flag
1
0x01 for high temperature; 0x00 for normal operation
Whenhightemperature isdetected,the shutdownflag willbesetto0x01,and thesystem willshutdown after
60 s. The flag remains 0x01 during the 60 s and the shutdown period
When the system is no longer in high temperature status, the shutdown flag will be reset to 0x00 and the
system will automatically return to normal operation
Reserved
3
-
Motor Speed
2
speed_2_bytes [15:0] = speed (RPM)
Timestamp
4
The “μs time” part of the absolute time of this data packet (defined in Appendix II.1)
Unit: μs
Range: 0 to 1000000 μs (1 s)
Return Mode
1
0x37 for Strongest Return mode, 0x38 for Last Return mode, and 0x39 for Dual Return mode
Factory Information
1
0x42 (or 0x43)
Date & Time
6
Date and time in decimal: year, month, date, hour, minute, second
Additional Info
Additional Info: 4 bytes
Field
Bytes
Description
UDP Sequence
4
Sequence number of this UDP packet
1 to 0xFF FF FF FF in little endian format