User's Manual

Table Of Contents
54
Table 6.10 PTC_COMMAND_GET_CONFIG_INFO (continued)
udp_seq
1 byte
Whether the point cloud data will include a UDP sequence number field
0
UDP sequence OFF (default)
1
UDP sequence ON #1 (UDP sequence increments only when UDP packets are generated)
2
UDP sequence ON #2 (UDP sequence increments even though no UDP packet is generated outside the
specified azimuth FOV)
NOTENotapplicabletoPandarQTandPandar128.ThesetwomodelsalwayshavetheUDPsequenceON.
trigger_method
1 byte
0 -angle based 1 - time based (default)
return_mode
1 byte
0 -last return 1 - strongest return 2 - dual return
standby_mode
1 byte
0 -in operation 1 - standby
motor_status
1 byte
0x0* - cannot reverse the rotation direction
0x1* - supports reversing the rotation direction
0x*0 - currently rotating clockwise
0x*1 - currently rotating counterclockwise
vlan_flag
1 byte
0 - VLAN not in use 1 - VLAN in use
vlan_id
2 bytes
VLAN ID
clock_data_fmt
1 byte
0 GPRMC 1 GPGGA
NOTE Not applicable to PandarQT and Pandar128
noise_filtering
1 byte
0 OFF 1 ON
NOTE Not applicable to PandarQT and Pandar128
reflectivity_mapping
1 byte
0-Linear Mapping
1 - Non-linear Mapping
NOTE Not applicable to PandarQT and Pandar128
reserved
6 bytes
-
6.2.5
PTC_COMMAND_GET_LIDAR_STATUS
Command message payload
None