User's Manual

Table Of Contents
7
Mechanical Rotation
Scanning Method
SENSOR
905 nm
Wavelength
MECHANICAL/ELECTRICAL/OPERATIONAL
PTP Clock Accuracy
≤1 μs
1.4
Specifications
Channel 128
Laser Class
Class 1 Eye Safe
Range 0.3 to 200 m (at 10 reflectivity)
Ingress Protection IP6K9K
RangeAccuracy
±5 cm (0.3 to 1 m)
Dimensions
Height: 122.7 mm
±2 cm (1 to 200 m)
Top/Bottom Diameter: 118.00 / 116.00 mm
FOV (Horizontal)
360°
Operating Voltage
DC 9 to 48 V
Resolution (Horizontal)
Configurable on-the-fly
0.1°/0. (10Hz) 20 W (at 0.2° horizonalresolution)
0.2°/0.4° (20 Hz)
FOV (Vertical)
40° (-25° to +15°)
Weight
1.63 kg
DATA I/O
0.5° (+2° to +14°, -6°to -24°) DataTransmission UDP/IP Ethernet (1000Mbps)
(+14° to +15°, -24° to -25°)
Frame Rate
10 Hz, 20 Hz
Data Points Generated
Single Return: 4,608,000 points/sec (max)
Dual Return Mode:9,216,000 points/sec (max)
Dual Return(Strongest, Last)
Clock Source
GPS / PTP
PTP Clock Drift ≤1 μs/s
NOTE Specifications are subject to change without notice.
NOTE The range and horizontal resolution of each channel is shown in Appendix I (Channel Distribution).
NOTE Range accuracy as the average range error across all channels may vary with range, temperature and target reflectivity.
FDA
CERTIFICATIONS
Returns Single Return
Data Outputs Distance, Azimuth Angle, Intensity
Resolution (Vertical) 0.125° (-6° to+2°)
Operating Temperature
-40℃ to 85
Power Consumption 25 W (at 0.1° horizonal resolution)