User's Manual

56
I.2.2 Laser Firing Time of Each Channel
Assuming that the start time of Block n is tn, the laser firing time can be calculated as follows, with the timing uncertainty Δt 10 μs.
Table II.1 Laser Firing Time of Each Channel (To Be Continued)
Firing Sequence
Laser ID
Firing Time (μs)
Firing Sequence
Laser ID
Firing Time (μs)
1
1
tn + 25.71 + Δt + 2.31
17
17
tn + 25.71 + Δt + 36.61
2
2
tn + 25.71 + Δt + 4.37
18
18
tn + 25.71 + Δt + 38.67
3
3
tn + 25.71 + Δt + 6.43
19
19
tn + 25.71 + Δt + 40.73
4
4
tn + 25.71 + Δt + 8.49
20
20
tn + 25.71 + Δt + 42.78
5
5
tn + 25.71 + Δt + 10.54
21
21
tn + 25.71 + Δt + 44.84
6
6
tn + 25.71 + Δt + 12.60
22
22
tn + 25.71 + Δt + 46.90
7
7
tn + 25.71 + Δt + 14.66
23
23
tn + 25.71 + Δt + 48.95
8
8
tn + 25.71 + Δt + 16.71
24
24
tn + 25.71 + Δt + 51.01
9
9
tn + 25.71 + Δt + 19.16
25
25
tn + 25.71 + Δt + 53.45
10
10
tn + 25.71 + Δt + 21.22
26
26
tn + 25.71 + Δt + 55.52
11
11
tn + 25.71 + Δt + 23.28
27
27
tn + 25.71 + Δt + 57.58
12
12
tn + 25.71 + Δt + 25.34
28
28
tn + 25.71 + Δt + 59.63
13
13
tn + 25.71 + Δt + 27.39
29
29
tn + 25.71 + Δt + 61.69
14
14
tn + 25.71 + Δt + 29.45
30
30
tn + 25.71 + Δt + 63.74
15
15
tn + 25.71 + Δt + 31.50
31
31
tn + 25.71 + Δt + 65.80
16
16
tn + 25.71 + Δt + 33.56
32
32
tn + 25.71 + Δt + 67.86