Instructions / Assembly

HD Install 020320
Specifications / Rough-In Dimensions
Model(s):
Shutter
Size
Approx.
Area
Coverage
CFM
(airflow)
Spd
Sones
@ 5ft
Cord
Plug
End
Cord
Length
Rough-In
Height
Rough-In
Width
8SFV-H
8” 150 sq/ft 300 Var. 5.4 115 volt 9 Ft 8.5” 8.5”
10SFV-H
10” 200 sq/ft 650 Var. 6.2 115 volt 9 Ft 10.5” 10.5”
12SF3-H
12" 300 sq/ft 1100 3 6 115 volt 9 Ft 12.5” 12.5”
12SFV-H
12” 250 sq/ft 900 Var. 6 115 volt 9 Ft 12.5” 12.5”
16SF3-H
16” 325 sq/ft 1325 3 6.3 115 volt 9 Ft 16.5” 16.5”
16SFV-H
16” 350 sq/ft 1400 Var. 6.4 115 volt 9 Ft 16.5” 16.5”
18SFV-H
18” 400 sq/ft 1785 Var. 7.4 115 volt 9 Ft 18.5” 18.5”
18SF-H
18” 800 sq/ft 3130 Var. 7.3 115 volt 9 Ft 18.5” 18.5”
20SF3-H
20" 775 sq/ft 2860 3 6.8 115 volt 9 Ft 20.5” 20.5”
20SFV-H
20" 900 sq/ft 3340 Var. 7 115 volt 9 Ft 20.5” 20.5”
24SF2-H
24" 1300 sq/ft 4450 2 7.4 115 volt 9 Ft 25” 25”
24SFV-H
24" 1300 sq/ft 4450 Var. 7.4 115 volt 9 Ft 25” 25”
30SF-H
30” 1750 sq/ft 5895 1 7 115 volt 9 Ft 31” 31”
36SF-H
36” 2200 sq/ft 8860 1 8.3 115 volt 9 Ft 37” 37”
Installation / Tools Needed
Typical Tools/Materials Needed: May vary due to wall materials.
Drill/bits/phillips bit, circular or recipricating saw, ratchet/Socket set, sealant/caulking, mounting fasteners (not included)
Installation Tips
Locate rough-in opening within 7 feet of existing 115v outlet to ensure cord reaches outlet.
Cut rough-in through desired wall. If needing to use wood to frame rough-in, ensure final rough-in dimensions match
those in chart below for corresponding size shutter mounted exhaust fan.
Fasten securely to wall with at least 4 screws/bolts & washers (at least one in each corner through existing holes).
Shutter Mounted Exhaust Fans