Installation Instructions

©2017 Hestan Commercial Corporation
3
EN
LOCATING THE SUITE
When determining a suitable location for your suite, take into account concerns such as exposure
to wind, rain, sprinklers, proximity to traffic paths, and keeping any gas supply line runs as short
as possible.
Locate the grill only in a well-ventilated area. Never locate the grill in a building, breezeway, shed
or other such enclosed areas without an approved ventilation system. Never locate the grill over,
under, or next to unprotected combustible construction.
During heavy use, the grill will produce a lot of heat and smoke. The grill is designed to take in
cool air at the front control panel area, and send the combustion products and smoke out the
exhaust gap at the rear of the hood. It is important to maintain this flow at all times. Using the
grill in windy areas can disrupt this proper flow and cause damage to your grill, or result in burn
hazards to the user. See Fig. 1 for details.
The Hestan Outdoor Living suite features ventilation openings (louvers) on each end. These
openings must be clear to avoid accumulation of gas should there be a leak. These openings are
further described later in this manual.
Figure 1
CURB INSTALLATION
1. The Hestan Outdoor Living Suite must be located on a level concrete or masonry patio
surface, not on direct soil. A licensed plumber and electrician should run their service
lines to the suite area prior to installation of the curb, in accordance with local codes. See
dimensions below for recommended location. See ELECTRICAL ITEMS section of this
manual for details. The gas line to the suite will require a shut-off that is easily accessible.
Local codes may also require a tracer wire be buried alongside the gas line for underground
detection. See the GAS CONNECTIONS section of this manual, and the appliance manual(s)
for more details.