Use and Care Manual

©2018 Hestan Commercial Corporation
35
EN
TROUBLESHOOTING GUIDE
Symptom Check
Burner will not light Gas supply not on / shutoff valve closed
LP gas cylinder empty
Power cord not plugged in, or no power to receptacle, or blown
fuse
Low gas pressure to unit
Burner ports near igniter are obstructed or dirty
Burner not installed correctly on orifice
Defective or clogged burner valve
Incorrect orifice or clogged orifice
Igniter defective (not glowing)
Defective regulator or regulator installed improperly
Burner will not stay lit Burner ports obstructed or dirty
Vent plugged on regulator or regulator installed improperly
Windy conditions
Low gas pressure
Slow to heat up Low gas pressure or low LP cylinder
Burner ports are obstructed or dirty
Defective or clogged burner valve
Incorrect orifice or clogged orifice
Gas Odor Burner went out or did not light
Loose or broken gas line
Ruptured pressure regulator
Burner not installed correctly on orifice
Poor combustion, air-fuel mixture not adjusted properly
Obstructed/dirty burner ports
Burner not working well / lazy
or yellow flame
Burner ports are obstructed or dirty, check for spider webs
Poor combustion, air-fuel mixture not adjusted properly
Gas pressure incorrect / incorrect regulator
Orifice sized incorrectly for gas type
Rotisserie will not light or will
not stay lit
Not holding in the control knob long enough
Windy conditions
Igniter defective (not glowing)
Power cord not plugged in, or no power to receptacle
Interior halogen lights not
working
Power cord not plugged in, or no power to receptacle
Check for burned-out bulb or fuse
Control panel LED lights not
working
Power cord not plugged in, or no power to receptacle
Check fuse on electrical box.
Rotisserie motor not working Power cord not plugged in, or no power to receptacle
Obstruction or broken chain-drive mechanism – call for service
Side burner will not light See “Burner will not light” above
Nuisance clicking of side
burner
Windy conditions
Flame too low
Food debris on electrode