TO TEST
Make sure all control valves are in the “OFF” position.
Apply the soap solution described above to all fittings.
Turn the gas supply on.
Check all connections from the supply line, or LP cylinder up to and including the manifold pipe
assembly.
Soap bubbles will appear where a leak is present. If a leak is present, immediately turn off gas supply,
tighten any leaking fittings, turn the gas supply back on, and recheck.
If you cannot stop a gas leak, turn off the gas supply and call the dealer where you purchased your
grill.
Do not use the grill or side burner until all connections have been checked and do not leak.
IMPORTANT NOTE - ALWAYS CHECK FOR LEAKS AFTER EVERY LP CYLINDER CHANGE.
BURNER / VALVE ADJUSTMENTS
Consult the GAS CONNECTIONS section of your Hestan or Aspire outdoor appliance for full
instructions on burner adjustments, flame appearance, air shutter adjustment, and valve adjustments.
This step is very important to ensure successful burner performance after conversion to the new fuel
type, or changing orifices for high altitude locations.
TESTING & ADJUSTMENT
(continued)