NG to LP Piped Systems Kit Guide

©2017 Hestan Commercial Corporation
8
EN
CHANGING ORIFICES - SIDE BURNER
(continued)
3. Use a nut driver or deep socket wrench (9/32” or 7 mm) to remove the two orifices from the orifice
holder. Install the new orifices and remount the burner base in the same manner it was removed.
Repeat this process for the secondary burner if applicable.
TESTING & ADJUSTMENT
LEAK TESTING
GENERAL
A complete gas tightness check must be performed of all gas-carrying components due to possible
movement during installation, or excessive pressure unknowingly being applied to parts of the unit.
BEFORE TESTING
Do not smoke while leak testing.
Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water for leak testing purposes.
Apply the solution to the gas fittings by using a spray bottle or a brush.
For LP units, always check with a full LP cylinder.