Use & Care Manual
©2021 Hestan Commercial Corporation
11
EN
W
H
D
LAYOUT FOR
NON-COMBUSTIBLE
ENCLOSURE (ISLAND)
36.0
91.4
REF.
3.5" [8.9] SQUARE
OPENING FOR
ELECTRICAL
2.5
6.4
MIN.
OPENING FOR
ACCESS DOORS
3.5" [8.9] SQUARE
OPENING FOR
GAS SUPPLY
18.8
47.8
1.2
3
1.5
3.8
0.8
2.1
6.50 REF.
16.5
TOP VIEW
TYPICAL ISLAND
INSTALLATION
(36" GRILL SHOWN)
.56 1.4
NOTCH
1.00 2.5 MAX.
COUNTERTOP
OVERHANG
30.0
76.2
2 OPENINGS
FOR GAS &
ELECTRICAL
FINISHED
COUNTERTOP
SEE NOTES ON
VENTILATION
OPENINGS
0.5
1.3
INSTALLATION - NON-COMBUSTIBLE CONSTRUCTION
(continued)
20.3
FRONT VIEW
36.0
91.4
REF.
120VAC - 15AMP
GFCI PROTECTED
OUTLET
FINISHED
COUNTERTOP
REAR VENT OPENINGS
RECOMMENDED.
SEE NOTES ON
VENTILATION OPENINGS.
DIMENSIONS IN [ ] ARE IN CM.
8 MIN.
7" X 11" [18 X 28]
ELECTRICAL BOX
LOCATED ON INSIDE
REAR WALL OF
ENCLOSURE
30" [76.2 cm] typical island depth shown to allow for clearance at the
rear of the grill for opening the hood. Assuming 2.50" [6.4 cm]
construction elements (studs) in the island, the electrical box mounts
to the rear wall of the island and is 3.25" [8.3 cm] deep. Certain
cabinets (such as AESDR36) installed in the island require clearance
so as to not interfere with the electrical box. Do not install one of
these cabinets directly in front of the electrical box. You may need
access to change a fuse, or to perform other service.
*
-
SIDE VIEW
3.5
9
24.27
61.7
5.25
13.3
OPTIONAL
CABINET
AESDR36
*
3.25
8.3
23.38
59.4
2.50
6.4
*
30.0
76.2
*