NG To LP Piped Systems Kit

©2017 Hestan Commercial Corporation
3
EN
MODIFYING REGULATOR
(continued)
2. Connect to your LP Piped System using a minimum 1/2” diameter flexible (semi-rigid) stainless steel
gas hose. The gas line connectors must comply with the
Standard for Connectors for Outdoor Gas
Appliances and Manufactured Homes, ANSI Z21.75 • CAS 6.27
, and suitable for outdoor installation.
The connection shall be 6 feet (1.82 m) or less.
NOTE: To ensure proper heating performance of this appliance, verify that the supply pressure is
adequate (11.0” WC supply pressure is preferred) to maintain 10.0” WC manifold pressure.
GAS SUPPLY
The local gas authority or supplier should be consulted at the installation planning stage in order
to establish the availability of an adequate supply of LP gas. If it is a new installation, have the gas
authorities or supplier check the meter size and piping to assure that the unit is supplied with the
necessary amount of gas supply and pressure to operate the unit(s).
Gas connections should be made by a qualified plumber, or your professional outdoor appliance service
technician.
All fixed (non-mobile) appliances must be fitted with an accessible upstream gas shutoff valve as a means
of isolating the appliance for emergency shut off and for servicing.
Make certain new piping and connections have been made in a clean manner and have been purged so
that piping compound, chips, etc. will not clog regulators, valves, orifices, or burners. Use pipe joint
compound / thread sealant approved for LP gas.