Use and Care Manual

©2021 Hestan Commercial Corporation
15
EN
W
H
D
SEE NOTES ON
VENTILATION
OPENINGS
2 OPENINGS
FOR GAS &
ELECTRICAL
FINISHED
COUNTERTOP
3.5" [8.9] SQUARE
OPENING FOR
ELECTRICAL
TYPICAL ISLAND
INSTALLATION WITH
INSULATION JACKET
1.0 2.5
MAX.
COUNTERTOP
OVERHANG
INSULATION
JACKET
REQUIRED
(36" GRILL SHOWN)
LAYOUT FOR
COMBUSTIBLE
ENCLOSURE (ISLAND)
WITH INSULATION JACKET
2.5
6.4
MIN.
OPENING FOR
ACCESS DOORS
4.2
10.6
3.5" [8.9] SQUARE
OPENING FOR
GAS SUPPLY
3.1
7.9
3.8
9.7
1.5
3.8
TOP VIEW
18.8
47.8
36.0
91.4
REF.
30.0
76.2
4.75
12.1
REF.
(in) (cm) (in) (cm) (in) (cm)
30” GRILL 35 88.9 25.1 63.8 12.8 32.5 AGIJ30
36” GRILL 41 104.1 25.1 63.8 12.8 32.5 AGIJ36
42” GRILL 47 119.4 25.1 63.8 12.8 32.5 AGIJ42
GRILL MODEL
W D H
INSULATION
JACKET P/N
INSTALLATION - COMBUSTIBLE CONSTRUCTION
(continued)
*
*
*
*
-
30.0
76.2
5.25
13.3
2.50
6.4
OPTIONAL
CABINET
AGLP36
10" X 11" [25 X 28]
ELECTRICAL BOX
LOCATED ON INSIDE
REAR WALL OF
ENCLOSURE
3.25
8.3
23.38
59.4
7.63
19.4
28.25
71.8
SIDE VIEW
FRONT VIEW
REAR VENT OPENINGS
RECOMMENDED.
SEE NOTES ON
VENTILATION OPENINGS.
FINISHED
COUNTERTOP
INSULATION
JACKET
REQUIRED
36.0
91.4
REF.
120VAC - 15AMP
GFCI PROTECTED
OUTLET
8 MIN.
20.3
- 30" [76.2 cm] typical island depth shown to allow for clearance at the
rear of the grill for opening the hood. Assuming 2.50" [6.4 cm]
construction elements (studs) in the island, the electrical box mounts
to the rear wall of the island and is 3.25" [8.3 cm] deep. Certain
cabinets (such as AGLP36) installed in the island require clearance
so as to not interfere with the electrical box. Do not install one of
these cabinets directly in front of the electrical box. You may need
access to change a fuse, or to perform other service.
DIMENSIONS IN [ ] ARE IN CM.