INSTALLATION
CLEARANCES:
TO NON-COMBUSTIBLE CONSTRUCTION
A minimum of 4” (10 cm) clearance from the back of the grill to non-combustible construction is
required to allow the hood to be opened fully.
TO COMBUSTIBLE CONSTRUCTION
This appliance should NOT be installed over, under or next to unprotected combustible
construction. If your enclosure (island) is combustible, then an insulated jacket manufactured
by Hestan, is required. See INSULATED JACKET dimensions below to make allowances in your
enclosure for this item. A minimum clearance to vertical combustible material is 12” (30 cm) on
the sides and the rear of the appliance.
The minimum vertical clearance to combustible materials means that ALL combustible materials
must be outside this 12” (30 cm) zone. As an example, if you have an island with a stucco or
tiled surface and wood-frame construction beneath, the wood is considered combustible, even
though the grill is touching the stucco or tile surface, which is non-combustible. In extreme
circumstances, the wood could potentially get hot enough to burn.
VENTILATION OPENINGS
A minimum of three 10 in² (65 cm²) of ventilation openings must be provided for both left and
right sides of your enclosure (island), as well as the back. These openings are required to safely
dissipate gas vapors if there is a leak in your enclosure.