Installation Instructions

EN
©2020 Hestan Commercial Corporation
5
If unit has been laid on its back or sides, place unit upright and allow a minimum of 24 hours before
connecting power.
PLUMBINGPLUMBING
No plumbing connections are required. Condensate from the cooling coil is automatically
evaporated through a condensate pan located in the condensing section of the unit.
ELECTRICAL SHOCK HAZARDELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing appliance. Failure to do so can
result in death or electrical shock.
ELECTRICAL GROUNDINGELECTRICAL GROUNDING
This appliance must be grounded. Grounding reduces the risk of electric
shock in the event of a short circuit.
DO NOT ground to a gas pipe.
DO NOT use an extension cord with this appliance.
DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in the NEUTRAL or
GROUNDING circuit could result in an electrical shock.
ELECTRICAL SUPPLYELECTRICAL SUPPLY
A 115 volt AC, 60 Hz, 15 Amp circuit breaker and electrical supply is required. A Ground Fault Circuit
Interrupter (GFCI) protected circuit must be used when installed outdoors.
This appliance is NOT designed for installation in manufactured (mobile) homes or recreational park
trailers.
All units are provided with a 5 ft [1.5 m] cord with three-prong grounding plug. It is imperative that
this plug be connected to a properly grounded three-prong receptacle. If the receptacle is not the
proper grounding type, contact an electrician. The receptacle must be flush or recessed into the wall
surface behind the unit.
Never remove the grounding prong from this plug.
Never use a 2-prong adapter.
Never use an extension cord to connect power to the unit.
If a 2-prong receptacle is encountered, or a longer power cord is required, contract a qualified
electrician to have it replaced in accordance with applicable electrical codes.
Do not attempt to operate the equipment on any other power source than that listed on the
Electrical Specification Plate attached to the unit.
ADDITIONAL GENERAL INFORMATIONADDITIONAL GENERAL INFORMATION
All electrical instructions assume the outlet is located 4 - 10” [10 - 25 cm] above the floor surface.
Floor must be level in area of installation. Leg levelers are used for fine-tune adjustment only and
should not be used to compensate for floor differences exceeding 1/2” [13 mm].
DANGER
SAFETY
(continued)