Installation Sheet
©2018 Hestan Commercial Corporation
9
EN
* The ventilation opening is to extend the full length of the cooktop cutout.
4”
[101mm]
min
24” [610mm]
min
36”
[915 mm]
25” [635 mm]
min
19 7/16” [494 mm]
3”
[76 mm]
[64mm]
2 1/2”
1/4”
[6mm]
min
2 1/2”
[65 mm]
27 1/4”
[692 mm]
4 3/4”
[120 mm]
1 1/2”
[38 mm]
min
1 5/8”
[40 mm]
max
*1/4”
[6 mm]
min
COOKTOP INSTALLATION
(CONT.)
NOTICE
Use the countertop opening dimensions that are given with these Instructions.
• Check the cooktop base for an approved installation label. Verify approved oven model
numbers that can be installed with your cooktop model number.
• The cooktop may be installed over a single oven.
• The cooktop should be centered over the oven.
• Both the cooktop and the oven must be installed according to each specific installation
instruction.