Installation Manual
ManualsBrandsHestan ManualsBottom Mount Refrigerators36 Inch Built-In Bottom Freezer Refrigerator with Bottom Compressor, EvenFlow Air Circulating Technology™, Dual Variable Speed Compressors, FreshZone™, Adjustable Shelves, Adjustable Door Bins, EverCrisp™ Drawers, Stainless Steel Interior, Digital Control
©2018 Hestan Commercial Corporation
10
ELECTRICAL AND WATER CONNECTION
(continued)
LOCATION AND INSTALLATION
E
W
E
W
E
W
E
W
E
W
E
W
The appliances are delivered from the factory for operation at 110V-
120V AC - 60Hz (US and Canada).
They are provided with a suitable supply cable and plug to be con-
nected  to  an  appropriate  15A  socket  (US  and  Canada)  provided 
with an effective grounding.
A circuit breaker  should  also be installed and should be  easily  ac-
cessible so that it can be easily switched off before performing any 
installation or maintenance.
To connect to the water supply system (for appliances equipped with 
ice makers) a 1/4” waterline with accessible shut-off valve must be 
supplied.
The appliance is provided with a water adapter elbow which is suit-
able for high water pressure and complies the Food Regulations.
The water lter cartridge , which is provided with the appliance
should be installed according to the accompanying instructions. Use 
only the new adapter which is supplied with the appliance. The so-
lenoid  connection on  the appliance  is 3/4”  diameter  but  is  metric 
threaded. A standard garden  hose threaded connector such as  a 
braided  stainless  hose found at typical hardware stores will strip or 
damage the solenoid threads. Use only the supplied 1/4” quick con-
nect elbow adapter for connecting a 1/4” copper or polyethylene 
source water line to the appliance.
Electrical cord length: 2000 mm (78 3/4”)
Water connection line length: 2500 mm (98 3/8”)
Do  not  use  extension  cords  and/or  multiple  adapters  for  the  power 
supply connection.
The appliance should be connected only to 
a drinkable water supply system.
to drink any water which is not suitable for 
human consumption.
Electrical and water supply behind the unit
Do not use extension cords or adapters.
Once  the appliance is  fully  installed,  con-
nected to the water supply (if applicable) and 
operational, in the event that the water sup-
ply must be turned off,(touch the button 
on 
control panel to switch it off) before the main 
water is shut off to prevent the appliance from 
entering a ‘NO WATER IN’ alarm state.
The built-in Hestan lter cannot make it safe
KRP Models
All other Models
EN