4-WIRE CONNECTION4-WIRE CONNECTION
For installations where grounding through the neutral
conductor is prohibited. Use only 4-conductor cord
kits rated 125/250 Volts (min), 50 Amps, and labeled
“For Use with Ranges”. Your Hestan range is pre-wired
at the factory for a 4-wire connection and includes this
cordset.
1. Make sure power is off at the supply panel /
breaker.
2. Remove the narrow access panel at the rear of
the range and locate the chassis ground terminal.
Attach GREEN ground appliance wire of supply
circuit or cord to chassis using ground screw.
3. Connect WHITE neutral appliance wire to WHITE
neutral wire in electrical box.
4. Connect RED (L1) appliance wire to RED power
wire in electrical box.
5. Connect BLACK (L2) appliance wire to BLACK
power wire in electrical box.
6. Tighten all connections. Strain relief must be
installed.
STRAIN RELIEF /
BRIDE DE CORDON
POWER CORD /
CORDON D’ALIMENTATION
GROUND TERMINAL /
BLOC DE MISE
À LA TERRE
3-WIRE CONNECTION3-WIRE CONNECTION
For installations where grounding through the neutral
conductor is allowed. Use only 3-conductor cord kits
rated 125/250 Volts (min), 50 Amps, and labeled “For
Use with Ranges”. This cordset is available at hardware
stores and home centers.
1. Make sure power is off at the supply panel / breaker
off.
2. Attach WHITE neutral appliance wire to WHITE
neutral wire in electrical box and use GREEN
ground jumper wire to connect to neutral as shown
here.
3. Connect RED (L1) appliance wire to RED power
wire in electrical box.
4. Connect BLACK (L2) appliance wire to BLACK
power wire in electrical box.
5. Tighten all connections. Strain relief must be
installed.
STRAIN RELIEF /
BRIDE DE CORDON
POWER CORD /
CORDON D’ALIMNENTATION
GROUND TERMINAL /
BLOC DE MISE
À LA TERRE
JUMPER WIRE /
FIL CONNECTEUR
ELECTRICAL CONNECTIONS