Installation Manual
Table Of Contents
- SAFETY PRECAUTIONS - BEFORE YOU BEGIN
- MODEL NUMBERS
- RATING LABEL
- REGULATORY / CODE REQUIREMENTS
- LOCATION AND INSTALLATION / VENTILATION
- BACKGUARD AND ACCESSORIES
- INSTALLATION OF ANTI-TIP DEVICE
- ELECTRICAL CONNECTIONS
- GAS CONNECTION
- FINAL SETUP
- SERVICE
- APPENDIX
- PRÉCAUTIONS DE SÉCURITÉ - AVANT DE COMMENCER
- NUMÉROS DE MODÈLE
- PLAQUE SIGNALÉTIQUE
- RESPECT DE LA RÉGLEMENTATION ET DES CODES EN VIGUEUR
- EMPLACEMENT ET INSTALLATION / VENTILATION
- DOSSERET ET ACCESSOIRES
- INSTALLATION DU DISPOSITIF ANTI-BASCULEMENT
- BRANCHEMENTS ÉLECTRIQUES
- RACCORDEMENT DE GAZ
- PHASE FINALE DE L’INSTALLATION
- SERVICE
- APPENDICE
EN
©2020 Hestan Commercial Corporation
9
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
18” [45.7]
MIN.
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
VENT HOOD
COMBUSTIBLE
MATERIALS
4”
[10.2]
11”
[27.9]
23”
[58.4]
7”
[17.8]
ELECTRICAL
SUPPLY
LOCATION
1-1/2”
[3.8]
12”
[30.5]
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
FINISHED
FLOOR
[45.7]
18”
INSTALLATION CLEARANCES WITH LOW BACKGUARD
FRONT VIEW
48"
W
V
E
G
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
RANGE MODEL
W
V (MIN)
KRD485GD 48” [121.9] 30” [76.2]
KRD484GD 48” [121.9] 30” [76.2]
NOTES:
• SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS
ARE NOT ALLOWED.
• APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE
ADJACENT COUNTERTOP SURFACES.
• “G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
• “E” IS ELECTRICAL SUPPLY ZONE.
• “W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
• “V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.