Installation Manual
Table Of Contents
- SAFETY PRECAUTIONS - BEFORE YOU BEGIN
- MODEL NUMBERS
- RATING LABEL
- REGULATORY / CODE REQUIREMENTS
- LOCATION AND INSTALLATION / VENTILATION
- BACKGUARD AND ACCESSORIES
- INSTALLATION OF ANTI-TIP DEVICE
- ELECTRICAL CONNECTIONS
- GAS CONNECTION
- FINAL SETUP
- SERVICE
- APPENDIX
- PRÉCAUTIONS DE SÉCURITÉ - AVANT DE COMMENCER
- NUMÉROS DE MODÈLE
- PLAQUE SIGNALÉTIQUE
- RESPECT DE LA RÉGLEMENTATION ET DES CODES EN VIGUEUR
- EMPLACEMENT ET INSTALLATION / VENTILATION
- DOSSERET ET ACCESSOIRES
- INSTALLATION DU DISPOSITIF ANTI-BASCULEMENT
- BRANCHEMENTS ÉLECTRIQUES
- RACCORDEMENT DE GAZ
- PHASE FINALE DE L’INSTALLATION
- SERVICE
- APPENDICE
EN
©2019 Hestan Commercial Corporation
17
4-WIRE CONNECTION
For installations where grounding through the neutral 
conductor is prohibited. Use only 4-conductor cord 
kits rated 125/250 Volts (min), 50 Amps, and labeled 
“For Use with Ranges”. Your Hestan range is pre-wired 
at the factory for a 4-wire connection and includes this 
cordset.
1.  Make sure power is off at the supply panel / 
breaker.
2.  Remove the narrow access panel at the rear of 
the range and locate the chassis ground terminal. 
Attach GREEN ground appliance wire of supply 
circuit or cord to chassis using ground screw.
3.  Connect WHITE neutral appliance wire to WHITE 
neutral wire in electrical box.
4.  Connect RED (L1) appliance wire to RED power 
wire in electrical box.
5.  Connect BLACK (L2) appliance wire to BLACK 
power wire in electrical box.
6.  Tighten all connections. Strain relief must be 
installed. 
STRAIN RELIEF / 
BRIDE DE CORDON
POWER CORD / 
CORDON D’ALIMENTATION
GROUND TERMINAL / 
BLOC DE MISE
À LA TERRE
3-WIRE CONNECTION
For installations where grounding through the neutral 
conductor is allowed. Use only 3-conductor cord kits 
rated 125/250 Volts (min), 50 Amps, and labeled “For 
Use with Ranges”. This cordset is available at hardware 
stores and home centers.
1.  Make sure power is off at the supply panel / breaker 
off.
2.  Attach WHITE neutral appliance wire to WHITE 
neutral wire in electrical box and use GREEN 
ground jumper wire to connect to neutral as shown 
here.
3.  Connect RED (L1) appliance wire to RED power 
wire in electrical box. 
4.  Connect BLACK (L2) appliance wire to BLACK 
power wire in electrical box.
5.  Tighten all connections. Strain relief must be 
installed. 
STRAIN RELIEF / 
BRIDE DE CORDON
POWER CORD / 
CORDON D’ALIMNENTATION
GROUND TERMINAL / 
BLOC DE MISE
À LA TERRE
JUMPER WIRE / 
FIL CONNECTEUR
ELECTRICAL CONNECTIONS 
(CONTINUED)