Specification Sheet

48” DUAL FUEL
RANGES
www.hestanhome.com phone 888.905.7463
3375 E. La Palma Ave., Anaheim, CA 92806CONTACT US:
GAS REQUIREMENTS : ⁄” NPT gas connection.
Minimum gas supply is 7” water column for natural
gas and 11” for propane. Operating pressure at the
manifold is 5” water column for natural gas and 10”
for propane. All units require a regulated gas
supply. (included)
ELECTRICAL REQUIREMENTS
:
208/
240V, 60Hz, 50 amps
KRD484GD-NG/-LP 48” Range 4 Burner with 24” Griddle
50 Amp
50 Amp 650
650
KRD485GD-NG/-LP 48” Range 5 Burner with 12” Griddle
48” 24-1/2”
107, 000
122, 000
48” 24-1/2”
ALL
Models
Description
W (in.) D (in.)
Total
Btu’s
Circuit
Breaker Req
Griddle
BTU
Cutout Dimensions
Approx
SHP WT (lbs)
15,000
15,000 (left)
15,000 (right)
Hestan Indoor products are approved for indoor
use only. Hestan Commercial Corporation reserves the
right to change materials and specications without
notice. Specify type of gas when ordering.
RANGE
MODEL
w
v
(min)
KRD485GD 48” [121.9]
48” [121.9]
30” [76.2]
KRD484GD 30” [76.2]
48-5/16”
122.7
3”
7.6
30-13/16”
78.3
24-11/16”
62.7
12”
30.5
LOCATION OF GAS
AND ELECTRICAL
ON FLOOR
ISLAND
TRIM
For Island Trim installations,
counter surface should
have a cantilever surface
meeting the rear of
the Island Trim
MIN. CLEARANCE
TO COMBUSTIBLE
SURFACES WITH
ISLAND TRIM
MAX.
RECESS
DEPTH
COOKING
SURFACE
APPLIANCE TOP
COMBUSTIBLE
MATERIALS
INSTALLATION CLEARANCES WITH ISLAND TRIM
SIDE VIEW
FRONT VIEW
NOTES:
* SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
* APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
* "G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS
POSSIBLE IN THIS ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
* "E" IS ELECTRICAL SUPPLY ZONE.
* "W" IS APPLIANCE OPENING.
* "V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
38-3/8 - 36-7/8”
[97.5 - 93.6]
TO COOKING
SURFACE
W
1-1/2”
3.8
4”
10.2
24”
61
V
12”
30.5
11”
27.9
23”
58.4
7”
17.8
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
ELECTRICAL
SUPPLY
LOCATION
G
FINISHED
FLOOR
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
E
COMBUSTIBLE
MATERIALS
37-1/4 - 35-3/4”
[94.6 - 90.8]
TO APPLIANCE
TOP
021898 REV A
KRD485GD
KRD484GD