Installation Manual

EN
©2019 Hestan Commercial Corporation
12
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
12”
[30.5]
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
FINISHED
FLOOR
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
COMBUSTIBLE
MATERIALS
DIMENSIONS IN
BRACKETS [ ]
ARE IN CM.
3”
[7.6]
5”
[12.7]
6”
[15.2]
5”
[12.7]
2-1/2”
[6.4]
19”
9-1/2”
[24.1]
ELECTRICAL
SUPPLY
LOCATION
[48.3]
[45.7]
18”
INSTALLATION CLEARANCES 36” WITH ISLAND TRIM
FRONT VIEW
W
V
G
E
RANGE MODEL
W
V (MIN)
KRD365 36” [91.4] 30” [76.2]
KRD364GD 36” [91.4] 30” [76.2]
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
“E” IS ELECTRICAL SUPPLY ZONE.
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.