Installation Manual
EN
©2019 Hestan Commercial Corporation
7
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
TO COOKING
SURFACE
48-5/16”
[122.7]
”61/31-03
[78.3]
”61/11-42
[62.7]
12”
[30.5]
3”
[7.6]
ISLAND
TRIM
For Island Trim installations,
counter surface should
have a cantilever surface
meeting the rear of
the Island Trim
MIN. CLEARANCE
TO COMBUSTIBLE
SURFACES WITH
ISLAND TRIM
MAX.
RECESS
DEPTH
COOKING
SURFACE
APPLIANCE
TOP
COMBUSTIBLE
MATERIALS
SIDE VIEW
LOCATION OF GAS
AND ELECTRICAL
ON FLOOR
36-7/8 - 38-3/8”
[93.6 - 97.5]
W
V
12”
[30.5]
FINISHED
FLOOR
COMBUSTIBLE
MATERIALS
11”
[28]
18”
[45.7]
G
11”
[28]
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
ELECTRICAL
SUPPLY
LOCATION
5”
[12.7]
E
2-1/2”
[6.4]
6”
[15.2]
3”
[7.6]
FRONT VIEW
DIMENSIONS IN
BRACKETS [ ]
ARE IN CM.
INSTALLATION CLEARANCES WITH ISLAND TRIM
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
VENTILATION REQUIREMENTS
It is strongly recommended that this appliance be installed with a Hestan vent hood. Due to the high
heat output of this range, it is very important that the hood and ductwork installation meets local
building codes and is installed by a qualified technician.
Do not use a down-draft style ventilation system.
Do not mount a microwave oven/ventilator combination above the range. These type of units do not
have sufficient airflow to remove the high heat output of this range and were not tested with this
type of appliance.
For non-Hestan approved vent hoods, the vent hood and/or blower unit must be rated for 1 CFM [1.7
m³/hr] for every 100 BTU [.03 kW]. (See rating plate for BTU rating of your unit.)
• If the range has a 12” Griddle, add an additional 200 CFM [340 m³/hr] to the blower capacity.
RANGE MODEL
W V (MIN)
KRG365 36” [91.4] 30” [76.2]
KRG364GD 36” [91.4] 30” [76.2]
NOTES:
*
SHADED AREAS INDICATE WHERE COMBUSTIBLE
MATERIALS ARE NOT ALLOWED.
*
APPLIANCE TOP MUST BE LEVEL OR HIGHER
THAN THE ADJACENT COUNTERTOP SURFACES.
*
"G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS
POSSIBLE
IN THIS ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
*
"E" IS ELECTRICAL SUPPLY ZONE.
*
"W" IS APPLIANCE OPENING.
*
"V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.