Installation Manual

EN
©2020 Hestan Commercial Corporation
9
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
“E” IS ELECTRICAL SUPPLY ZONE.
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
VENT HOOD
COMBUSTIBLE
MATERIALS
ELECTRICAL
SUPPLY
LOCATION
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
FINISHED
FLOOR
INSTALLATION CLEARANCES WITH LOW BACKGUARD
FRONT VIEW
48"
W
V
G
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
5-7/8”
[2.3]
1-3/4”
[4.4]
[45.7]
18”
18” [45.7]
MIN.
12”
[30.5]
2”
[5.1]
6”
[15.2]
6”
[15.2]
9”
[22.9]
E
RANGE MODEL
W V (MIN)
KRG485GD 48” [121,9] 30” [76,2]
KRG484GD 48” [121,9] 30” [76,2]