INSTALLATION OF ANTI-TIP DEVICE 
(CONTINUED)
DRYWALL INSTALLATION: After positioning the bracket as per the diagram below, mark the holes 
and drill the appropriate holes as per the instructions supplied with the wall anchors. For hardboard 
or solid plaster walls, you may need different wall anchors, available at your local hardware store or 
home center.
WOOD FLOOR INSTALLATION: After positioning the bracket as per the diagram below, mark the 
holes and drill the appropriate holes for #12 or similar, large wood screws, at least 1.5” [3.8 cm] in 
length. Use washers as well. All hardware is available at your local hardware store or home center.
CONCRETE FLOOR INSTALLATION: After positioning the bracket as per the diagram below, mark 
the holes and drill the appropriate holes for #12 or similar large masonry anchors, at least 1.5” [3.8 
cm] in length. Use washers as well. All hardware is available at your local hardware store or home 
center.
ANTI-TIP BOLT ADJUSTMENT 
After leveling the range, and after the bracket 
has been attached, adjust the anti-tip bolt and 
large washer under the range so the top of the 
washer is 1-1/4” [3.2 cm] maximum from the 
floor. Slide the range into the opening of the 
bracket and verify the bolt is engaged in the 
bracket as seen below. Carefully tip the range 
forward to check. The range should not move 
more than 1” [2.5 cm].