Installation Manual

©2019 Hestan Commercial Corporation
5
EN
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
INSTALLATION CLEARANCES WITH LOW BACKGUARD
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
18” [45.7]
MIN.
W
V
12”
[30.5]
9-1/2”
[24.1]
28-1/2”
[72.4]
10”
[25.4]
2”
[5.1]
7-1/2” [19] MAX.
OPENING
HEIGHT
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
FINISHED
FLOOR
VENT HOOD
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
G
E
ELECTRICAL
SUPPLY
LOCATION
PLATFORM
COMBUSTIBLE
MATERIALS
FRONT VIEW
APPLIANCE
TOP
COOKING
SURFACE
71.6
13” [33]
MAX.
37-1/8”
[94.3]
TO COOKING
SURFACE
28-1/2”
[72.4]
24-1/2” [62] MAX.
PLATFORM
7-1/2” [19]
MAX.
OPENING
HEIGHT
LOW
BACKGUARD
COMBUSTIBLE
MATERIALS
SIDE VIEW
28-3/16”
LEVELING
The rangetop must be level, especially those models featuring a
griddle. Raise to the desired height by placing shims underneath
the unit as needed.
CAUTION
The appliance top must be level or higher than the adjacent
countertop surfaces. Failure to adjust the height may expose
the adjacent cabinets to excessive heat which may damage the
cabinets or countertop.
REF 1.12”
[2.84 cm]
COOKING
SURFACE
APPLIANCE
TOP
REF 1.12”
[2.84 cm]
RANGETOP
MODEL
W
V (MIN)
KRT304 30” [76.2] 30” [76.2]
KRT365 36” [91.4] 30” [76.2]
KRT364GD 36” [91.4] 30” [76.2]
KRT485GD 48” [121.9] 30” [76.2]
KRT484GD 48” [121.9] 30” [76.2]
SHADED AREAS INDICATE WHERE COMBUSTIBLE
MATERIALS ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE
ADJACENT COUNTERTOP SURFACES.
"G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT
SHUT-OFF VALVE AS HIGH AS
POSSIBLE IN THIS ZONE
FOR EASY ACCESS WHEN RANGETOP IS INSTALLED.
"E" IS ELECTRICAL SUPPLY ZONE.
"W" IS APPLIANCE OPENING.