Installation Manual

©2018 Hestan Commercial Corporation
6
EN
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
W
9-1/2”
24.1
2”
5.1
V
12”
30.5
28-1/2”
72.4
10”
25.4
7-1/2” [19] MAX.
OPENING
HEIGHT
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
ELECTRICAL
SUPPLY
LOCATION
G
FINISHED
FLOOR
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
E
PLATFORM
12”
30.5
28-1/2”
72.4
24-1/2” [62] MAX.
PLATFORM
7-1/2” [19] MAX.
OPENING
HEIGHT
28-3/16”
71.6
37-1/8”
94.3
TO COOKING
SURFACE
ISLAND
TRIM
For Island Trim installations,
counter surface should
have a cantilever surface
meeting the rear of
the Island Trim
MIN. CLEARANCE
TO COMBUSTIBLE
SURFACES WITH
ISLAND TRIM
COOKING
SURFACE
APPLIANCE TOP
COMBUSTIBLE
MATERIALS
COMBUSTIBLE
MATERIALS
INSTALLATION CLEARANCES WITH ISLAND TRIM
FRONT VIEW
SIDE VIEW
NOTES:
* SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
* APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
* "G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE IN THIS ZONE
FOR EASY ACCESS WHEN RANGETOP IS INSTALLED.
* "E" IS ELECTRICAL SUPPLY ZONE.
* "W" IS APPLIANCE OPENING.
* "V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD OR COMBUSTIBLE SURFACE.
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
FRONT COOLING VENTS
NOTICE
When placing your rangetop in the cabinet, DO
NOT BLOCK or obstruct the front cooling vents
shown. These vents allow air into the appliance
to keep the internal electronic parts cool.
COOLING
VENTS