Installation Manual
Table Of Contents
- SAFETY PRECAUTIONS - BEFORE YOU BEGIN
- MODEL NUMBERS
- RATING LABEL
- REGULATORY / CODE REQUIREMENTS
- LOCATION AND INSTALLATION / VENTILATION
- BACKGUARD AND ACCESSORIES
- ELECTRICAL CONNECTIONS
- GAS CONNECTION
- FINAL SETUP
- SERVICE
- APPENDIX
- PRÉCAUTIONS DE SÉCURITÉ - AVANT DE COMMENCER
- NUMÉROS DE MODÈLE
- PLAQUE SIGNALÉTIQUE
- RESPECT DE LA RÉGLEMENTATION ET DES CODES EN VIGUEUR
- EMPLACEMENT ET INSTALLATION / VENTILATION
- DOSSERET ET ACCESSOIRES
- BRANCHEMENTS ÉLECTRIQUES
- RACCORDEMENT DE GAZ
- PHASE FINALE DE L’INSTALLATION
- SERVICE
- APPENDICE
©2020 Hestan Commercial Corporation
9
EN
Installation of this cooking appliance must be made in accordance with local codes. In the absence of 
local codes, this unit should be installed in accordance with the National Fuel Gas Code No. 
Z223.1/ 
NFPA 54
, Natural Gas and Propane Installation code 
CSA B149-1
, or Propane Storage and Handling 
Code B149.2.
NOTE:NOTE: See rating label for manifold pressure for the type of gas of your appliance.
CONNECTING THE GAS CONNECTING THE GAS   
Some rangetop units may have the regulator mounted 
internally as seen in Figure A. There is a short flex hose 
which extends below the rear of the rangetop. This 
short flex hose has a connection end with 1/2”NPT 
internal thread AND 3/4”NPT external threads. The 
installer must connect a gas supply hose at this location.
Other units have the regulator located externally with 
a short flex hose at the rear of the rangetop as shown 
in Figure B. The regulator is shipped loose in the 
accessory box with other items. The regulator must 
be connected to the provided short flex hose by the installer, and 
then the gas supply hose to the inlet side of the regulator. Make a 
note of the flow arrow embossed on the regulator itself. The arrow 
points toward the range. The gas inlet of the regulator is 1/2”NPT 
thread. 
Connect to the gas supply using a mininum 3/4” inside diameter 
(1”OD) flexible (semi-rigid) stainless steel gas hose (not included) 
with appropriate fittings to prevent gas starvation. This 
hose should be no more that 36” [91.4 cm] in length. Use the 
appropriate thread sealant on all connections, except flare fittings.
The supply line must not interfere with the rear of the rangetop. 
Use caution when pushing the rangetop against the back wall, so 
that you do not kink or crimp the flex hose as this could result in a 
gas leak. 
CONVERSION KITSCONVERSION KITS
In the event your Hestan appliance needs to be converted from 
NG to LP, or vice-versa, you will need to contact Hestan Customer 
Service to arrange a service call. This conversion should only be 
performed by a qualified technician.
HIGH ALTITUDE KITSHIGH ALTITUDE KITS
If you live in a high altitude area, 2,000 ft. [610 m] or more above sea level, your appliance may 
require different orifices for proper combustion and performance. You will need to contact Hestan 
Customer Service to arrange a service call. High Altitude kits must be installed by a qualified 
technician. Please have your model and serial number information ready when you call. 
1/2”NPT
INTERNAL THREAD
FIGURE A: INTERNAL REGULATOR
3/4”NPT
EXTERNAL THREAD
1/2” NPT THREAD
FIGURE B: EXTERNAL REGULATOR 
GAS CONNECTION 
(CONTINUED)