LOCATION AND INSTALLATION/VENTILATION 
(CONTINUED)
GAS
SUPPLY
TO
APPLIANCE
SHUTOFF VALVE
IN OPEN POSITION
PREPARATIONPREPARATION
Before moving the rangetop, 
remove the grates, burner caps, 
and any other loose items.
The rangetop must be mounted 
on a stable platform, as illustrated 
here and on the following pages. 
The platform must include a 
6” x 12” [15 x 30 cm] cutout at 
the left rear to allow for the gas 
and electrical connections. The 
platform must also be level to 
ensure an even cooking surface, 
especially for those models 
featuring a griddle. The platform 
should be a minimum of 3/4” 
[19 cm] thick to support the 
weight of the unit. For large units 
48” [1.2m] and wider, a center 
structural element inside the 
cabinet, under the platform, may 
be necessary. 
GAS AND ELECTRICAL SUPPLY CLEARANCESGAS AND ELECTRICAL SUPPLY CLEARANCES
If not already in place, install a gas shut-off valve in an 
easily accessible location for servicing of the rangetop. 
Make sure all users of the rangetop know where this shut-
off is located, and how to shut off the gas. Any openings in 
the wall or floor behind the appliance must be sealed. The 
Installation Clearances on the following pages show where 
the “G” and “E” zones should be located.
CABINETRYCABINETRY
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space 
located above the surface units should be avoided. If cabinet storage is to be provided, the risk can 
be reduced by installing the required vent hood that projects horizontally a minimum of 5” [12.7 cm] 
beyond the bottom of the cabinets.
  12
[30]
6
[15]
3/4" THICK
PLATFORM