LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
G
E
W
V
COMBUSTIBLE
MATERIALS
6”
[15.2]
MIN. CLEARANCE
TO COMBUSTIBLE
SURFACES WITH
ISLAND TRIM
12”
[30.5]
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
COOKING
SURFACE
APPLIANCE
TOP
7-1/2” [19]
MAX.
OPENING
HEIGHT
ISLAND
TRIM
For Island Trim installations,
counter surface should
have a cantilever surface
meeting the rear of
the Island Trim
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
28-1/2”
[72.4]
24-1/2” [62] MAX.
PLATFORM
[71.6]
TO COOKING
SIDE VIEW
28-3/16”
37-1/8”
[94.3]
SURFACE
28-1/2”
[72.4]
10”
[25.4]
PLATFORM
9-1/2”
[24.1]
2”
[5.1]
ELECTRICAL
SUPPLY
LOCATION
FINISHED
FLOOR
FRONT VIEW
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
COMBUSTIBLE
MATERIALS
INSTALLATION CLEARANCES WITH ISLAND TRIM
7-1/2” [19] MAX.
OPENING
HEIGHT
FRONT COOLING VENTSFRONT COOLING VENTS
NOTICE
When placing your rangetop in the cabinet, DO NOT
BLOCK or obstruct the front cooling vents shown.
These vents allow air into the appliance to keep the
internal electronic parts cool.
COOLING
VENTS
RANGETOP
MODEL
W
V (MIN)
KRT304 30” [76.2] 30” [76.2]
KRT365/KRTS365 36” [91.4] 30” [76.2]
KRT364GD 36” [91.4] 30” [76.2]
KRT485GD 48” [121.9] 30” [76.2]
KRT484GD 48” [121.9] 30” [76.2]
SHADED AREAS INDICATE WHERE COMBUSTIBLE
MATERIALS ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE
ADJACENT COUNTERTOP SURFACES.
"G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT
SHUT-OFF VALVE AS HIGH AS
POSSIBLE IN THIS ZONE
FOR EASY ACCESS WHEN RANGETOP IS INSTALLED.
"E" IS ELECTRICAL SUPPLY ZONE.
"W" IS APPLIANCE OPENING.