Installation Guide
Table Of Contents
- SAFETY PRECAUTIONS - BEFORE YOU BEGIN
- MODEL NUMBERS
- RATING LABEL
- REGULATORY / CODE REQUIREMENTS
- LOCATION AND INSTALLATION / VENTILATION
- BACKGUARD AND ACCESSORIES
- ELECTRICAL CONNECTIONS
- GAS CONNECTION
- FINAL SETUP
- SERVICE
- APPENDIX
- PRÉCAUTIONS DE SÉCURITÉ - AVANT DE COMMENCER
- NUMÉROS DE MODÈLE
- PLAQUE SIGNALÉTIQUE
- RESPECT DE LA RÉGLEMENTATION ET DES CODES EN VIGUEUR
- EMPLACEMENT ET INSTALLATION / VENTILATION
- DOSSERET ET ACCESSOIRES
- BRANCHEMENTS ÉLECTRIQUES
- RACCORDEMENT DE GAZ
- PHASE FINALE DE L’INSTALLATION
- SERVICE
- APPENDICE
©2021 Hestan Commercial Corporation
9
EN
Installation of this cooking appliance must be made in accordance with local codes. In the absence of 
local codes, this unit should be installed in accordance with the National Fuel Gas Code No. 
Z223.1/ 
NFPA 54
, Natural Gas and Propane Installation code 
CSA B149-1
, or Propane Storage and Handling 
Code B149.2.
NOTE:NOTE: See rating label for manifold pressure for the type of gas of your appliance.
CONNECTING THE GAS CONNECTING THE GAS 
Rangetop units have the regulator installed at the factory. However, a short flex hose is shipped 
loose in the accessory box with other items and must be installed. The installer must temporarily 
remove the rear cover to make the connection. Connect the short flex hose to the elbow on the 
regulator inlet as shown here. Use the appropriate thread sealant on the connections.
Connect the gas supply to the other end of the short 
flex hose as shown here. Use a mininum 3/4” inside 
diameter (1”OD) flexible (semi-rigid) stainless steel gas 
hose (not included) with appropriate fittings to prevent 
gas starvation. This hose should be no more that 36” 
[91.4 cm] in length. Use the appropriate thread sealant 
on all connections, except flare fittings. Please perform 
the leak check before re-installing the rear cover.
The supply line must not interfere with the rear of the 
rangetop. Use caution when pushing the rangetop 
against the back wall, so that you do not kink or crimp 
any hoses as this could result in a gas leak. If there is 
a cabinet or other storage below the rangetop, be sure 
no items can interfere or bump into the gas hoses. 
CONVERSION KITSCONVERSION KITS
In the event your Hestan appliance needs to be 
converted from NG to LP, or vice-versa, you will need 
to contact Hestan Customer Service to arrange a 
service call. This conversion should only be performed 
by a qualified technician.
HIGH ALTITUDE KITSHIGH ALTITUDE KITS
If you live in a high altitude area, 2,000 ft. [610 m] or more above sea level, your appliance may 
require different orifices for proper combustion and performance. You will need to contact Hestan 
Customer Service to arrange a service call. High Altitude kits must be installed by a qualified 
technician. Please have your model and serial number information ready when you call. 
INTERNAL REGULATOR CONNECTION
FLEX HOSE
SHIPPED
LOOSE
CONNECT GAS
SUPPLY HOSE HERE
ELBOW
GAS CONNECTION 
(CONTINUED)