INSTALLATION
  TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 
PERSONS, OBSERVE THE FOLLOWING: 
a)  Installation work and electrical wiring must be done by qualified person(s) in accordance with 
all applicable codes and standards, including fire-rated construction. 
b)  Sufficient air is needed for proper combustion and exhausting of gases through the flue 
(chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment 
manufacturer’s guideline and safety standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society for Heating, Refrigeration, and Air 
Conditioning Engineers (ASHRAE) and the local code authorities.
c)  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden 
utilities. 
d)  Ducted fans must always be vented to the outdoors. 
 TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. 
TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT USE THIS BLOWER WITH 
ANY SOLID-STATE SPEED CONTROL DEVICE.
INSTALLATION DETAILS
1.  Read all instructions thoroughly before beginning installation. Note: These instructions apply 
to Hestan hoods only. 
•  See “DUCTING DO’S AND DON’TS” on page10 
•  Weight and size: For safe installation, at least two people should be present to lift and hold the 
hood. For larger hoods and installations with duct covers, it is advisable to have a third person 
present to assist.
•  Back Venting: If venting out the wall behind the hood instead of venting through the ceiling, 
see “BACK VENTING” on page16 for details. 
2.  When installing a wall mount range hood, it is recommended that the bottom edge of the hood 
be located no more than 30” above the cooking surface for optimum performance.
3.  Duct Preparation
IF THE HOOD IS TO BE “BACK VENTED”, PROCEED DIRECTLY TO 
STEP 4.
a)  Consult the connection diagrams (following) for further details on 
exhaust outlet placement.
b)  Install the duct(s) from the outside of the home down to the 
location of the exhaust outlet(s) on the top of the hood allowing 
room for the transition (if applicable). If a transition is used, install 
duct down to the location of the transition outlet plus 1”. This will 
allow the transition to engage 1” inside of duct.
c)  Use foil HVAC tape (not gray cloth duct tape) to seal all joints. See 
“VENT ACCESSORIES” on page17 for a listing of Hestan ducting 
accessories.
Make sure that once the hood is mounted, the 
motor cooling vents are not obstructed.
30”
[76.2 cm]
 9”
[22.9 cm]
 9”
[22.9 cm]
36”
[91.4 cm]
Optional duct 
cover
©2019 Hestan Commercial Corporation
11
EN