Owners Guide

CONNECTION HEIGHTS:CONNECTION HEIGHTS:
The hood will mount to a suitable srtucture or to an (optional) duct cover. The hood height and duct
length will be determined by the height of the mounting surface.
Dual Blower (T200 = 550 CFM):
Top of included transition is 3” above top of hood.
The duct should extend to 2” above the hood mounting surface.
Quad Blowers (T400 = 1100 CFM):
Top of included transition is 5-1/4” above top of hood.
The duct should extend to 4-1/4” above the hood mounting surface.
CONNECTION DIAGRAMS CONNECTION DIAGRAMS
Included transition
8” [20.3 cm] round outlet
Vent holes
Connection Diagram (36, 42” models)
T200 Dual Blower (550 CFM ) (Top View)
Electrical
Centerline
of hood
Centerline
of hood
7-3/4”
[19.7 cm]
Included transition: 12” outlet
5-1/4” [13.3 cm] above top of hood
Electrical (2)
Connection Diagram (54” model)
T400 - Quad Blowers (1100 CFM) (Top View)
Vent holes
Centerline
of hood
Centerline
of hood
7-3/4”
[19.7 cm]