Owners Guide

INSTALLATION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
a) Load-bearing framework in the ceiling is necessary for the installation of an island hood.
Additional framework construction may be required. Do not attach an island hood to a structure
that cannot support twice the weight of the hood and (optional) duct covers. For weights of
hoods, see the Dimensions table on page13, and “Duct Covers” on page16.
b) Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction.
c) Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE) and the local code authorities.
d) When cutting or drilling into ceiling, do not damage electrical wiring and other hidden utilities.
e) Ducted fans must always be vented to the outdoors.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT USE THIS BLOWER WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
INSTALLATION DETAILSINSTALLATION DETAILS
1. Read all instructions thoroughly before beginning installation. Note: These instructions apply to
Hestan’s hoods only.
See “DUCTING DO’S AND DON’TS” on page10.
Weight and size: For safe installation, at least two people should be present to lift and hold the
hood. For larger hoods and installations with duct covers, it is advisable to have a third person
present to assist. For weights of hoods, see the Dimensions table on page13, and “Duct Covers”
on page16.
2. When installing an island hood, it is recommended that the bottom edge of the hood be located
no more than 30” above the cooking surface for optimum performance.
3. If using a duct cover:
a) Remove the duct cover from its packaging and remove the
hood-mounting screws from the base of the duct cover.
b) Install the duct cover to the load-bearing framework in the
ceiling using appropriate hardware through the four inside
corner mounting flanges on the top of the duct cover.
4. Install the duct from outside the home, down to the location of
the exhaust outlet on the top of the included transition of the
hood, plus 1”. This will allow the transition to engage 1” inside
of the duct. Consult the connection diagrams (on next page) for
further details on exhaust outlet placement.
Use foil HVAC tape (not grey cloth duct tape) to seal all joints.
See “VENT ACCESSORIES” on page15 for a listing of available
Hestan ducting materials.
Optional duct
cover
30”
[76.2 cm]
18”
[45.7 cm]
36”
[91.4 cm]
©2020 Hestan Commercial Corporation
11
EN