Installation Guide
INSTALLATION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with
all applicable codes and standards, including fire-rated construction.
b) Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE) and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
d) Ducted fans must always be vented to the outdoors.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT USE THIS BLOWER WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
INSTALLATION DETAILS
1. Read all instructions thoroughly before beginning installation. Note: These instructions apply
to standard hood inserts only. Custom hood inserts may require additional specification
consideration.
• Back Venting: If venting out the wall behind the vent instead of venting through the ceiling, see
“Back Venting” on page 14 for particulars.
2. When installing a Hestan hood insert, it is recommended that the bottom edge of the insert be
located no more than 30” above the cooking surface for optimum performance.
3. Install the duct(s) from the outside of the house down to the location
of the exhaust outlet(s) on the top of the liner, allowing room for the
optional transitions, if used.
If back venting, the elbows should be installed so that the non-crimped
end(s) are on the inside of the collar(s) of the exhaust outlet(s).
If a transition is used, install the duct so it will engage 1” of the
transition outlet.
Consult the connection diagrams (following) for further details on
exhaust outlet placement.
Use foil HVAC tape (not gray cloth duct tape) to seal all joints. A
complete listing of suggested ducting materials is provided on the back
page of this instruction sheet.
TRANSITION HEIGHTS:
Dual Blower (WM2L, 600 CFM): no transition - 8” round duct will
connect directly to the top of the hood.
Cabinet with
vent liner
30”
[76.2 cm]
36”
[91.4 cm]
©2018 Hestan Commercial Corporation
11