Installation Guide
Single and Dual Blower (WM1L + WM2L, 900 CFM): 6” round duct will connect directly to the
top of the hood; 8” round will connect directly to the top of the hood.
Or use optional multi-blower transition (AKVT6810, sold separately). See “Vent
Accessories” on page 16.t
Two Dual Blowers (Two WM2Ls, 1200 CFM):
Two 8” round ducts connect directly to the top of the hood.
Or use optional multi-blower transition (AKVT8812, sold separately). See “Vent
Accessories” on page 16.
CONNECTION DIAGRAMS
Motor
Cooling
Vent
Electrical
WM2L Dual Blower (600 CFM ) (Top View)
Wall side
Centerline
of hood
Connection diagram (30-36” width)
8" [20.3 cm] round
5 1/2"
[14 cm]
1 3/4"
[4.4 cm]
5 1/4"
[13.3 cm]
8" Round
Connection Diagram (42” Width)
WM2L Dual + WM1L Single Blower (900 CFM) (Top View)
Wall side
Centerline
of hood
Electrical (2)
Motor
Cooling
Vent (3)
6" [15.2 cm]
round
7 5/16"
[18.6 cm]
1 7/8"
[4.8 cm]
5 1/4"
[13.3 cm]
1 3/4"
[4.4 cm]
7 5/16"
[18.6 cm]
5 1/2"
[14 cm]
Electrical (2
)
Connection Diagram (48”- 54” Widths)
Two WM2L Dual Blowers (1200 CFM) (Top View)
Wall side
Centerline
of hood
Motor
Cooling
Vent (4)
8"
[20.3 cm] round
5 1/2"
[14 cm]
1 3/4"
[4.4 cm]
5 1/4"
[13.3 cm]
11"
[29.9 cm]
11"
[29.9 cm]
8"
[20.3 cm] round
INSTALLATION
(CONT.)
©2018 Hestan Commercial Corporation
12
EN