Datasheet

System Unit
System UnitSystem Unit
System Unit
Tower Dimensions
Tower DimensionsTower Dimensions
Tower Dimensions
(H x W x D)
(with feet/bezel)
18.5 x 8.59 x 23.46 in (47 x 21.8 x 59.6 cm)
Rack Dimensions
Rack DimensionsRack Dimensions
Rack Dimensions
(H x W x D)
(with feet/bezel)
8.54 x 17.5 x 21.9 in. (21.7 x 44.5 x 55.7cm)
Tower Weight
Tower WeightTower Weight
Tower Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
70 lb (31.8 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
54 lb (24.5 kg)
Rack Weight
Rack WeightRack Weight
Rack Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
66 lb (29.9 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
48 lb (21.8 kg)
Input Requirements
Input RequirementsInput Requirements
Input Requirements
(per power supply)
Rated Line Voltage
100 to 240 VAC
Rated Input Current
7.1 Amps (at 120VAC) to 3.5 Amps (at 240
VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
852 W
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at
240 VAC)
1200W - 3530 BTU / hr (at 120 VAC), 4600 (at
240 VAC)
Power Specifications
Power SpecificationsPower Specifications
Power Specifications
To review typical system power ratings use the HP Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-energy-efficient
- Click on the system of interest. Example: ML350 G6
- Follow the instructions of the next screens.
Power Supply Output
Power Supply OutputPower Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power
460(750) W (at 100 VAC),
460(750) W (at 200 VAC)
Maximum Peak Power
460(750) W (at 100 VAC),
460(750) W (at 200 VAC)
NOTE:
NOTE:NOTE:
NOTE:
See Power Supply Specifications tables
for complete details on 460W PSU and optional
750W and 1200W Power Supply Options.
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an