Data Sheet

QuickSpecs
Aruba 2530 Switch Series
Technical Specifications
Page 35
Aruba 2530 8 PoE+ Internal PS Switch (JL070A)
I/O ports and slots
8 RJ-45 autosensing 10/100 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-
TX, IEEE 802.3at PoE+); Media Type: Auto-MDIX; Duplex: half or full
2 dual-personality ports; each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type
10Base
-T; IEEE 802.3u Type 100Base-Tx; IEEE 802.3ab 1000Base-
T Gigabit Ethernet) or as a SFP slot
(for use with SFP transceivers) ports
Additional ports and
slots
1 dual-personality (RJ-45 or USB micro-B) serial console port
Physical characteristics
Dimensions
10(w) x 9.68(d) x 1.75(h) in (25.4 x 24.59 x 4.45 cm) (1U height)
Weight
4.65 lb (2.11 kg)
Memory and processor
Processor
ARM9E @ 800 MHz, 128 MB flash; Packet buffer size: 1.5 MB dynamically
allocated, 256 MB DDR3 DIMM
Mounting and enclosure
Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-mounting kit available);
Horizontal surface mounting; Wall mounting
Performance
IPv6 Ready Certified
100 Mb Latency
< 1.3 µs (LIFO 64-byte packets)
1000 Mb Latency
< 1.3
µ
s (LIFO 64-byte packets)
10 Gbps Latency
Throughput
up to 4.1 Mpps (64-byte packets)
Switching capacity
5.6 Gbps
MAC address table size
16000 entries
Environment
Operating temperature
32°F to 113°F (0°C to 45°C)
Operating relative
humidity
15% to 95% @ 104°F (40°C), noncondensing
Non-operating/
Storage temperature
-40°F to 158°F (-40°C to 70°C)
Non-operating/Storage
relative humidity
15% to 90% @ 149°F (65°C), noncondensing
Altitude
up to 10,000 ft (3 km)
Acoustic
Power: 0 dB, Pressure: 0 dB
Electrical characteristics
Frequency
50/60 Hz
Maximum heat
dissipation
29 BTU/hr (30.6 kJ/hr), (switch only: 29 BTU/hr; combined switch + max.
PoE devices: 239 BTU/hr)
Voltage
100 - 127 / 200 - 240 VAC, rated
Current
0.9/0.5 A
Maximum power rating
70.2 W
Idle power
5.3 W
PoE Power
67 W PoE
NOTES:
Idle power is the actual power consumption of the device with no ports
connected.
Maximum power rating and maximum heat dissipation are the worst-
case
theoretical maximum numbers provided for planning the infrastructure
with fully loaded PoE (if
equipped), 100% traffic, all ports plugged in, and
all modules populated.
PoE power is the total power budget available to all PoE ports.
Safety
UL 60950-1; CAN/CSA 22.2 No. 60950-1; EN 60825; IEC 60950-1; EN 60950-1