Datasheet

7
HP A5120 SI Switch Series
Specifications (continued)
HP A5120-24G-PoE+ SI Switch (JG091A) HP A5120-24G-PPoE+ SI Switch (JG092A)
Ports
24 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T,
IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at
PoE+); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
4 fixed Gigabit Ethernet SFP ports
1 RJ-45 serial console port
24 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T,
IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at
PoE+); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
4 fixed Gigabit Ethernet SFP ports
1 RJ-45 serial console port
Physical characteristics
Dimensions
16.54(d) x 17.32(w) x 1.72(h) in. (42 x 44.0 x 4.36 cm) (1U height) 16.54(d) x 17.32(w) x 1.72(h) in. (42 x 44.0 x 4.36 cm) (1U height)
Weight
15.43 lb. (7 kg) 15.43 lb. (7 kg)
Memory and processor
128 MB flash, 128 MB SDRAM; packet buffer size: 0.5 MB 128 MB flash, 128 MB SDRAM; packet buffer size: 0.5 MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included)
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included)
Performance
1000 Mb Latency
< 3 µs < 3 µs
Throughput
41.7 million pps 41.7 million pps
Routing/Switching capacity
56 Gbps 56 Gbps
Routing table size
32 entries 32 entries
Environment
Operating temperature
32°F to 113°F (0°C to 45°C) 32°F to 113°F (0°C to 45°C)
Operating relative humidity
10% to 90%, noncondensing 10% to 90%, noncondensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, noncondensing 5% to 95%, noncondensing
Electrical characteristics
Maximum heat dissipation
539 BTU/hr (568.65 kJ/hr) 290 BTU/hr (305.95 kJ/hr)
Voltage
100-240 VAC 100-240 VAC
DC voltage
-52 to -55 VDC
Maximum power rating
832 W 255 W
PoE power
720 W 170 W
Frequency
50 / 60 Hz 50 / 60 Hz
Notes
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules
populated.
PoE Power is the power supplied by the internal power supply, it is dependent
on the type and quantity of power supplies and may be supplemented with the
use of a External Power Supply (EPS).
With AC input, the Max power consumption is 523W (370W for PoE)
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules
populated.
PoE Power is the power supplied by the internal power supply, it is dependent
on the type and quantity of power supplies and may be supplemented with the
use of a External Power Supply (EPS).
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety
of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel;
ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS
Compliance
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety
of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel;
ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS
Compliance
Emissions
FCC part 15 Class A; VCCI Class A; EN 55022 Class A; CISPR 22 Class A;
ICES-003 Class A; ANSI C63.4 2003; ETSI EN 300 386 V1.3.3; AS/NZS
CISPR22 Class A; EN 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN
61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6; EN 61000-4-11;
EN 61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC
Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
FCC part 15 Class A; VCCI Class A; EN 55022 Class A; CISPR 22 Class A;
ICES-003 Class A; ANSI C63.4 2003; ETSI EN 300 386 V1.3.3; AS/NZS
CISPR22 Class A; EN 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN
61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6; EN 61000-4-11;
EN 61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC
Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Management
IMC - Intelligent Management Center; command-line interface; Web browser;
SNMP Manager
IMC - Intelligent Management Center; command-line interface; Web browser;
SNMP Manager