Datasheet
QuickSpecs
HP 5130 EI Switch Series
Technical Specifications
c04394228 — DA – 15058 Worldwide — Version 1 —September 29, 2014
Page 24
Mounting and enclosure
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)
Performance
1000 Mb Latency
< 5 µs
10 Gbps Latency
< 1.5 µs
Throughput
130.9 Mpps
Routing/Switching
capacity
176 Gbps
Routing table size
512 entries (IPv4), 256 entries (IPv6)
MAC address table size
16384 entries
Reliability
MTBF (years)
37.1
Environment
Operating temperature
32°F to 113°F (0°C to 45°C)
Operating relative
humidity
10% to 90%, noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
5% to 95%, noncondensing
Acoustic
Low-speed fan: 50.6 dB, High-speed fan: 54.6 dB; ISO 7779
Electrical characteristics
Frequency
50/60 Hz
Maximum heat
dissipation
160/1671 BTU/hr (168.8/1762.91 kJ/hr), for AC power. For DC power min
heat dissipation is 147BTU/hr and 3037BTU/hr max.
AC voltage
100 - 240 VAC
Current
10 A
Maximum power rating
490 W
Idle power
47 W
PoE power
370 W PoE+
Notes
Idle power is the actual power consumption of the device with no ports
connected. Maximum power rating and maximum heat dissipation are the
worst-case theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated. PoE Power is the power supplied by
the internal power supply. When supplemented with the use of an HP
RPS1600 Redundant Power System, up to 740 W of PoE+ can be supplied.
Max current rating for DC power is 25A. AC Input power is 47W typical, and
490W max(including 370W PoE+ consumption. DC Input voltage range is -
54 to -57VDC. Total DC input power is 43W typical and 890W with 800W
PoE+ Power consumption. DC Input voltage range is -54VDC to -57VDC. DC
Input Source is the HP RPS1600.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2;
IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR
Subchapter J; NOM; ROHS Compliance
Emissions
EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A; EN 61000-4-11:2004; ANSI C63.4-2009; EN
61000-3-3:2008; VCCI V-4/2012.04; EN 6100-3-2:2006+A1:2009 + A2:2009; EN 61000-3-
2:2006+A1:2009+A2:2009 ; EN 61000-4-3:2006; EN 61000-4-4:2012; EN 61000-4-5:2006; EN 61000-
4-6:2009; AS/NZS CISPR 22:2009 Class A; CISPR 22:2008 Class A; EN 55022:2010 Class A; EN 61000-4-
29: 2000; CISPR 24:2010; EN 300 386 V1.6.1; VCCI V-3/2013.04 Class A
Immunity
Generic
EN 55024
ESD
EN300 386
Management
IMC - Intelligent Management Center; command-line interface; Web browser; SNMP Manager
Services
Refer to the HP website at: www.hp.com/networking/services for details on the service-level