Specification Sheet

QuickSpecs
HPE ProLiant DL360 Gen10 Server
Technical Specifications
System Unit
Dimensions (Height x Width x Depth)
SFF Drives
4.29 x 43.46 x 70.7 cm
1.69 x 17.11 x 27.83 in
LFF Drives
4.29 x 43.46 x 74.98 cm
1.69 x 17.11 x 29.5 in
Weight
(approximate)
13.04 kg (28.74 lb)
SFF minimum: One drive, one processor, one power supply, two heatsinks, one Smart Array controller, and five fans.
16.27 kg (35.86 lb)
SFF maximum: 10 drives, two processors, two power supplies, two heatsinks, one Smart Array controller and seven
fans.
13.77 kg (30.36 lb)
LFF minimum: one drive, one processor, one power supply, two heatsinks, one Smart Array controller and five fans.
16.78 kg (37 lb)
LFF maximum: Four drives, two processors, two power supplies, two heatsinks, one Smart Array controller and seven
fans.
Input Requirements
(per power supply)
Rated Line Voltage
For 1600W (Platinum): 200-240 VAC
For 800W (Titanium) Power Supply: 200-240 VAC
For 800W (Platinum): 100-240 VAC
For 800W (Universal) Power Supply: 200-277 VAC
For 800W (-48VDC): -40 Vdc to -72 Vdc
500W (Platinum) Power Supply: 100-240 VAC
BTU Rating
Maximum
For 1600W Power Supply: 5918 BTU/hr (at 200 VAC), 5888 BTU/hr (at 220 VAC), 5884 BTU/hr (at 240 VAC)
For 800W (Titanium) Power Supply: 2905 BTU/hr (at 200 VAC), 2899 BTU/hr (at 220 VAC), 2893 BTU/hr (at 240 VAC)
For 800W (Platium) Power Supply: 3067 BTU/hr (at 100 VAC), 2958 BTU/hr (at 200 VAC), 2949 BTU/hr (at 240 VAC)
For 800W (Universal) Power Supply: 2964 BTU/hr (at 200 VAC), 2951 BTU/hr (at 230 VAC), 2936 BTU/hr (at 277 VAC)
For 800W-(48Vdc) Power Supply: 2983 BTU/hr (at -40 Vdc), 2951 BTU/hr (at -48Vdc), 2912 BTU/hr (at -72Vdc)
For 500W (Platinum) Power Supply: 1902 BTU/hr (at 100 VAC), 1840 BTU/hr (at 200 VAC), 1832 BTU/hr (at 240 VAC)