Operating Manual
Table Of Contents
- Cover.doc
- Title Page.doc
- Table of Contents.DOC
- Chapter 1 General Information.DOC
- Chapter 2 Equipment Setup.DOC
- Chapter 3 Installation.DOC
- Chapter 5 Operator Maintenance.doc
- Chapter 6 Troubleshooting.doc
- CHAPTER 6
- 6-1 INTRODUCTION
- 6-2 CLIENT STATION PROBLEMS
- Symptoms
- Causes on the CAP
- Causes on the client station or ground-based access point
- Symptoms
- Cause on the CAP
- Causes on the client station
- Symptoms
- Causes on the CAP
- Causes on the client station
- Other cause
- Symptoms
- Causes on the client station
- Symptoms
- Causes on the CAP
- Causes on a local client station
- Symptoms
- Causes
- 6-3 CAP PROBLEMS
- CHAPTER 6
- Chapter 7 Regulatory Wireless Interoperability Health.doc
- Glossary.DOC
Operator’s Manual M365-491
3-12 Chapter 3
March/2006 Installation
Table 3-1. I/O Connector J1 Pin Assignments
Pin* Signal Pin* Signal
1 Chassis Ground 22 Chassis Ground (Shield)
2 Reset 23 Ethernet LAN Port 2 Rx+
3 Reset Ground 24 Ethernet LAN Port 2 Tx+
4 No connection 25 Ethernet LAN Port 2 Tx-
5 No connection 26 Ethernet LAN Port 1 Rx-
6 No connection 27 Ethernet LAN Port 1 Tx-
7 No connection 28 Chassis Ground
8 Chassis Ground 29 Reserved
9 Ethernet LAN Port 2 Rx- 30 Reserved
10 Ethernet LAN Port 1 Rx+ 31 Reserved
11 Ethernet LAN Port 1 Tx+ 32 No connection
12 Chassis Ground 33 Digital Ground
13 Chassis Ground 34 Reserved
14 Discrete Input 1 (on/off control) 35 Reserved
15 Discrete Input 2 (RF enable/disable) 36 No connection
16 Reserved 37 28 VDC Return (901164-2, -3 only)
17 No connection 38 28 VDC Positive (901164-2, -3 only)
18 115 VAC Phase (hot) 39 Chassis Ground
19 115 VAC Neutral 40 Chassis Ground
20 Discrete Output 1 (on/off status) 41 Chassis Ground
21 Discrete Output 2 (RF status)
* Use M83723/77R2041N for mating connector.