Installation Guide

SAFEmine Ltd | www.safe-mine.com | support@safe-mine.com 18/39
SAFEmine (part of Hexagon Mining)
Baarerstrasse 133, CH-6300 Zug
Switzerland
www.hexagon.com
The QC250 SAFEmine devices include a self-contained WLAN module. The module is a complete
IEE 802.11 b/g/n based wireless device.
The module supports WPA2-PSK, WEP (64 and 128 bit) and TKIP security encryption.
The typical transmit power is 17dBm for 801.11b, 15dBm for 802.11g/n. The sensitivity is -97dBm @
1Mbps to -71dBm @65 MBps.
The connector is a reverse polarity female SMA (RP-SMA) with center pin contact and outside
threads for passive WiFi Antennas with 50 Ω wave impedance.
Only antennas supplied by SAFEmine may be used.
3.5.6.
Main Interface
The main interface has a 8-pin M12 male connector. This interface is connected to the vehicle and
optional add-on modules. It provides the connection points for power supply and communication
ports a dedicated voice signal line as well as one configurable digital I/O:
Pin
Color
Symbol
Function
Min.
Typ.
Max.
1
White
+V
batt
Power supply from Battery
+9V
dc
+12V
dc
+24V
dc
+28V
dc
2
Brown
-V
batt
Power ground from Battery,
connected internally to system
ground GND
-V
batt
3
Green
CAN-low
CAN-Bus Port (ISO-11898)
GND
+V
batt
4
Yellow
CAN-high
GND
+V
batt
5
Grey
Rx
Serial Communication Port
- QC23x: RS485
- QC220/2240/250: RS232
GND
+V
batt
6
Pink
Tx
7
Blue
I/O1
Configurable
1
Digital Input / Output
GND
+V
batt
8
Red
Audio
Signal wire for SM Voice output
GND
+V
batt
1
Please consult chapter 4.6 for general instructions on configuration of I/Os.
Use of CAN-Bus, Serial Port, I/O1 and Audio connection depends on the application. They may be
left unconnected if not used.
The main interface also includes a hardwired input (I/O0) which is internally connected to pin 1 in
order to monitor the power supply voltage.
The SAFEmine CAS system can operate with a supply voltage down to 9V
dc
, but if the supply voltage
is below 9.6V at startup, an error code or a message indicating the low supply power is displayed
and the device will refuse service. If the supply voltage drops below 9.6V during operation, the
powerLED will turn red and the error message is issued. In case the voice option is enabled error