Technical information

HGST Ultrastar C15K600 Hard Disk Drive Specification
188
PHY Capabilities are defined under the “SAS Speed Negotiation”
18.10.13
Mode Page 1A (Power Control)
Table 155 Page 1A (Power Control)
Byte
Bit
Default
7
6
5
4
3
2
1
0
0
PS
SPF (0b)
Page Code = 1Ah
9Ah
1
Page Length = 26h
26h
2
PM_BG_PRECEDENCE
Reserved = 0
Standby_Y
00h
3
Reserved = 0
Idle_C
Idle_B
Idle_A
Standby_Z
06h
4-7
Idle_A Condition Timer
14h
8-11
Standby_Z Condition Timer
00h
12-15
Idle_B Condition Timer
1770h
16-19
Idle_C Condition Timer
00h
20-23
Standby_Y Condition Timer
00h
24-38
Reserved
00h
39
CCF_IDLE
CCF_STANDBY
CCF_STOPPED
Reserved
58h
- If the STANDBY_Y bit is set to one, then the standby_y condition timer is enabled. If the STANDBY_Y bit is set
to zero, then the device shall ignore the standby_y condition timer.
- If the IDLE_C bit is set to one, then the idle_c condition timer is enabled. If the IDLE_C bit is set to zero, then the
device shall ignore the idle_c condition timer.
- If the IDLE_B bit is set to one, then the idle_b condition timer is enabled. If the IDLE_B bit is set to zero, then the
device shall ignore the idle_b condition timer.
- If the IDLE_A bit is set to one, then the idle_a condition timer is enabled. If the IDLE_A bit is set to zero, then the
device shall ignore the idle_c condition timer.
- If the STANDBY_Z bit is set to one, then the standby_z condition timer is enabled. If the STANDBY_Z bit is set
to zero, then the device shall ignore the standby_z condition timer.
- The IDLE_A Condition Timer field specifies the initial value, in 100 millisecond increments, for the idle_a power
condition timer. The minimum allowable inactivity time for idle_a is 1 second. Any value less than this is
accepted, but will automatically default to 1 second.
- The STANDBY_Z Condition Timer field specifies the initial value, in 100 millisecond increments, for the
standby_z power condition timer. The minimum allowable inactivity time for standby_z is 2 minutes. Any value
less than this is accepted, but will automatically default to two minutes. In addition, a limit of 60 timer initiated
head unloads per 24 hour period is enforced.
- The IDLE_B Condition Timer field specifies the initial value, in 100 millisecond increments, for the idle_b power
condition timer. The minimum allowable inactivity time for idle_b is 2 minutes. Any value less than this is
accepted, but will automatically default to two minutes. In addition, a limit 60 timer initiated head unloads per 24
hour period is enforced.
- The IDLE_C Condition Timer field specifies the initial value, in 100 millisecond increments, for the idle_c power
condition timer. The minimum allowable inactivity time for idle_c is 2 minutes. Any value less than this is
accepted, but will automatically default to two minutes. In addition, a limit of 60 timer initiated head unloads per
24 hour period is enforced.
- The STANDBY_Y Condition Timer field specifies the initial value, in 100 millisecond increments, for the
standby_y power condition timer. The minimum allowable inactivity time for standby_y is 2 minutes. Any value
less than this is accepted, but will automatically default to two minutes. In addition, a limit60 timer initiated head
unloads per 24 hour period is enforced.
- The PM_BG_PRECEDENCE field (see Table 153) specifies the interactions between background functions and