Technical information
HGST Ultrastar C15K600 Hard Disk Drive Specification
131
Table 103 Log Sense Page E (part 2 of 2)
Byte
Bit
7
6
5
4
3
2
1
0
12-13
Week of Manufacture (2 ASCII characters)
14-15
Parameter Code 0002h
16
DU=0
DS=0
TSD=0
ETC=0
TMC = 0
F&L = 00b
17
Parameter Length = 06h
18-21
Accounting Date Year (4 ASCII characters)
22-23
Accounting Date Week (2 ASCII characters)
24-25
Parameter Code 0003h
26
DU=0
DS=1
TSD=0
ETC=0
TMC = 0
F&L = 00b
27
Parameter Length = 04h
28-31
Specified cycle count over device lifetime
32-33
Parameter Code 0004h
34
DU=0
DS=1
TSD=0
ETC=0
TMC = 0
F&L = 00b
35
Parameter Length = 04h
36-39
Accumulated start-stop cycles (4 byte binary number)
40-41
Parameter Code 0005h
42
DU=0
DS=1
TSD=0
ETC=0
TMC = 0
F&L = 00b
43
Parameter Length = 04h
44-47
Specified load unload count over device lifetime
48-49
Parameter Code 0006h
50
DU=0 DS=1 TSD=0 ETC=0 TMC = 0 F&L = 00b
51
Parameter Length = 04h
52-55
Accumulated load unload cycles (4 byte binary number)
The week and year that the device was manufactured shall be set in the parameter field defined by parameter code
0001h. The date of manufacture cannot be saved using the LOG SELECT command. The data is expected in
numeric ASCII characters (30-39h) in the form YYYYWW. The accounting date specified by parameter code 0002h
is a parameter that can be saved using the LOG SELECT command.