Technical information

HGST Ultrastar C15K600 Hard Disk Drive Specification
336
21.5
TCG SSC Tables
Two copies of all TCG SCC tables and data structures are stored in the RID; one is used as a primary copy and the
other as a backup copy. The backup copy is used in the event the primary copy becomes corrupted. Each time a
write is executed to any TCG table, both the primary and backup copies of the tables are updated and saved in the
RID. In the case of a corrupted copy, the good copy is always used to restore the corrupted copy to the correct
state. If both copies of the tables become corrupted during operation, the tables will be reinitialized to default
values automatically, and this will result in a key mismatch error when a read is attempted.
The default values in the TCG tables created at the time of manufacturing are per the TCG SSC specification. The
following tables contain VU (Vendor Unique) entries, which are set at the time of manufacturing.
Admin SP C_PIN table
Locking C_PIN table
K_AES_256 table
Locking SP Locking Access Control table
Locking Info Table
Locking SP Locking Table
The VU entries for these tables are specified below. In addition, explanation of default values is given for non-VU
entries that require it.
21.5.1
Admin SP C_PIN Table and Locking SP C_PIN Table
Per TCG SSC specification, the PIN is set to the MSID at manufacturing time. HGST has specified the MSID to be
the serial number of the drive concatenated 4x. Try Limit is set to 0, meaning that there is no limit. Tries is set 0,
meaning that there have been no fail attempts. Persistence is set to 0, meaning the “Tries” value does not persist
through power cycles (The “Tries” value is reset to 0 after successful attempt or a power cycle).
Table 284 HGST Implementation of Admin SP_CPIN & Locking C_PIN
..
PIN
Try Limit
Tries
Persistence
..
MSID
0
0
0
..
MSID
0
0
0
..
..
..
..
..
..
MSID
0
0
0